Permit HC-BLD-26-0082643 is a commercial miscellaneous permit at 13420 S VILLAGE DR, with a declared valuation of $34,970, issued on 31 Mar 2026. Its recorded status is “Issued”. Issued by Hillsborough County (unincorporated).
01
The record
Hillsborough County (unincorporated) · fetched 31 Aug 2026, 07:59
Permit number
HC-BLD-26-0082643
Type
Commercial Miscellaneous
Description
Scope of Work – Electrical Repairs and New Installations Address: 13420 South Village Drive, Tampa, FL 33618 New Meter GPS: 28°04'03.01" N, 82°30'55.01" W All work shall be performed in strict accordance with the 2023 National Electrical Code (NEC) and the Florida Building Code. 1. Repair/maintain 3 light poles south of pond, including replacement of old junction boxes missing lids/screws (NEC 314.28 & 314.41). 2. Repair center soccer field light pole (between 2 buildings): troubleshoot/replace melted wiring and conductors (NEC 110.12 & 300.5). 3. Remove existing high-voltage oak tree lights (5+ fixtures tied to building). Install 100 W low-voltage transformer in concessions building. Run SCH 40 PVC conduit with direct-burial cable to 5 new 15 W low-voltage oak tree lights (NEC 411.3 & 300.5). 4. From one repaired pole south of pond: remove old transformer, install new 100 W low-voltage transformer, and run direct-burial cable in SCH 40 PVC to 1 new 5 W landscape light for bulletin board (NEC 411.3 & 300.5). 5. Repair/maintain 2 concession buildings: remove/replace old lighting with new LED wall packs and repair/replace subpanels as needed (NEC 410.16 & 408.36). 6. Install new 100 A meter at specified GPS location. From meter, run SCH 40 PVC conduit underground (290 ft total to farthest pole) to supply 3 new 12 ft metal light poles with 175 W LED luminaires (NEC 230.70 & 300.5). Installation of Three 12 ft Metal Light Poles Each pole with 3-bolt anchor base installed per NEC Articles 110, 210, 250, 300, 310, and 410. Foundation: 18 in. dia. Sonotube, 4 ft deep, 4,000–5,000 psi concrete, reinforced with 4 #4 vertical bars + #3 ties @ 12 in. o.c. (NEC 300.5 for underground support). Anchor Bolts: 3 ea. ¾ in. galvanized J/L-bolts projecting 3–4 in., with 2 nuts/washers each. Conduit & Conductors: SCH 40 PVC underground, #10 AWG THWN-2 copper conductors. Total wire length: 339 ft (NEC 300.5 & 310.10). Load Calculations & Voltage Drop: 3 × 175 W = 525 VA Continuous load (125 % per NEC 210.19(A)(1)): 656 VA Calculated current at 120 V: 5.47 A Circuit protection: 20 A breaker Wire size: #10 AWG THWN-2 copper Voltage drop: 3.73 % at 339 ft — acceptable per NEC 210.19(A)(1) Informational Note. Grounding: Each pole grounded with ? in. × 10 ft ground rod + #6 AWG bonding to base and rebar cage (NEC 250.52(A)(5) & 250.54). All work complies with NEC Articles 110, 210, 250, 300, 310, and 410.
Data as of 31 Aug 2026, 07:59 · updated nightly from Hillsborough County (unincorporated). This is a copy of a public record; the authoritative version is held by the agency. How we handle it · Report personal information on this page
Sunshine File
Built in Tampa from Florida public records under Chapter 119 and Art. I § 24. No mugshots. No search by a person’s name. No arrest records tied to individuals. Police calls are shown by block, never against a home.